I will be discussing some of the recommendation as published in DCA6-2015 (Prescriptive Residential Wood, Deck Construction Guide based on 2015 International Residential Code). This write up is in no way meant to summarize DCA6-2015.

I am not reproducing the document but rather I am highlighting some of the information in it in efforts to make more people aware of such a great resource (free) that is available at everyone fingertips DCA6-2015


Engineers are trained to interpret codes, standards and other requirements of the local jurisdiction, also to use their best engineering judgement, training and education when reliable sources aren't available.


In the pictures below information provided to help builders and home owners determine decks maximum joist spans and overhangs. There are a lot of information available to help people get their projects built, and some of it just free like DCA6 2015.


ree
ree
ree

ree


In the pictures below information provided to help builders and home owners determine decks’ maximum Beam Spans and overhangs also joist-to-beam connection detail as well as beam assembly detail.



ree

ree

ree

ree

ree



In the 2 figures below, I am sharing the recommended post to beam attachment requirements as noted in DCA6-2015.



ree

ree




This attachment below is an example of a prohibited post to beam attachment per DCA6-2015. It is important to note that per the article published in the Structure Magazine in April 17th and written by John Showalter, P.E. And Loren Ross, P.E. (Residential Wood Deck Design, https://www.structuremag.org/?p=11302 ).

They do state that" It is important to note that prohibiting attachment of the beam to the sides of the post with fasteners only ensures wood -to-wood bearing. The design of fasteners for wet-services conditions requires significant capacity reductions and should be evaluated by a design professional" Based on this statement a more detailed and maybe lengthy calculations would be required to determine whether this indicated attachment satisfy minimum code and engineering requirements or not. For many people avoiding that engineering expense would just simply to comply with the prescriptive code and eliminate such connection.


ree



In the Figures below you will see a few recommended attachment of ledger board to band joist/rim joist and to foundation wall, also you will see the prohibited attachment per DCA6-2015



ree


ree


Typical foundation options also discussed in DCA6-2015 as shown in the figure below


ree




Below you will see an example guard detail so builders and home owners can determine Guard Requirements for all decks that are 30" above grade.



ree


Examples of Guard Post attachments for required guard are shown in the few pictures below.


ree


ree

Pictures below Explain stair & stair stringer requirements also show tread connection, stair guard requirements and stair stringer attachment detail.



ree

ree

ree


I hope I was able to provide some highlights for this great document, DCA6-2015. Also refer back to IRC and IBC for any additional information that is necessary and not discussed in DCA6.


Call us today if you need any further assistance: 724-949-0004

www.pittdes.com


Written by Firas Abdelahad, P.E.

Firas Abdelahad has been a practicing structural engineer since 2005, collaborating with a diverse range of professionals, including consultants, architects, investors, homeowners, contractors, and subcontractors. Together, they tackle the various challenges that can arise during the design and construction phases of projects.


The information and statements in this document are for information purposes only and do not comprise the professional advice of the author or create a professional relationship between reader and author.





 
 
 
  • Writer: Firas Abdelahad
    Firas Abdelahad
  • Feb 19, 2022
  • 1 min read

Updated: Sep 17, 2024

Do I need a structural engineer to evaluate if I can add a fish tank in my house ?

Fish Tank
Fish Tank


I often get requests from different clients about the impact of an added fish tank to their living room floor. Generally speaking a small tank may have negligible impact but often times people wants to add rather bigger size tank.

Evaluating the floor joists and floor ability to support such an additional weight is a wise decision to prevent sagging floor, even if you think your floor joists are currently healthy and don't have any sag.


I made a small example of how to calculate the weight and determine if your floor can support the weight or not. The bigger the area you distribute the weight over, the less of an impact on the floor and its supporting joists.


I hope you find the information valuable and helpful.


Calculations sheet
Calculations sheet

Call us today if you need any further assistance: 724-949-0004


Written by Firas Abdelahad, P.E.

Firas Abdelahad has been a practicing structural engineer since 2005, collaborating with a diverse range of professionals, including consultants, architects, investors, homeowners, contractors, and subcontractors. Together, they tackle the various challenges that can arise during the design and construction phases of projects.


The information and statements in this document are for information purposes only and do not comprise the professional advice of the author or create a professional relationship between reader and author.

 
 
 


YAHOO NEWS
YAHOO NEWS


A structural engineer and local architect, work together offering more services in the city of Pittsburgh. Pittsburgh is known for its old and historic structures as well as its aging residential houses across Western Pennsylvania.

Restoring historic buildings maintains the original aesthetic and provides us with an educational tool for the history, art, architecture and engineering of the time period when the building was originally constructed. If there’s one thing to remember when preserving important and long-standing buildings, it’s to maintain their character. If you tamper with them too much, the building's charm and value will diminish.

A significant portion of the residential properties in Pittsburgh and its surrounding area are over 70 years old. Many of these properties are dealing with either ground water challenges, bowed or cracked foundation walls or bowed/bulged brick veneer (exterior façade).

Pittsburgh Design & Engineering Services is looking to help maintain the character of these historic buildings and old architectural shapes of Pittsburgh residential structures, while making sure they are structurally sound and can last safely many more years. They have worked and evaluated many structures that either were classified as a landmark or were located in the historic district in Pittsburgh.

Pittsburgh Design & Engineering Services LLC is excited about the opportunity to find and restore these historic and old building structures that mean so much to the communities and the great people of Pittsburgh. They enjoy assisting them throughout their design process whether they are renovating, rehabbing, restoring or reinforcing to maintain the structure longevity for years to come.

The owner, Firas Abdelahad, has said, "We understand the market, and we believe in velocity while we still offer quality work with fair cost. We fully believe in offering our clients the best quality, within their time frame while trying to stay on their budget to get the work done. We pride ourselves on being a value-added service even for the clients that may not hire us."

About Pittsburgh Design & Engineering Services, LLC: Locally owned, managed and operated structural engineering firm serving Pittsburgh and its surrounding areas. Pittsburgh Design & Engineering Services was established to assist architects, home owners, real estate agents, investors, general contractors, and developers to make their experience designing, buying, selling, remodeling, investing, or flipping properties smoother by providing them with a reliable structural engineering service when needed.

They would love to talk with you about your project, ask you a few questions and if they realize that you don't need a structural engineer they will let you know and provide you with recommendations on who can assist you. If you are looking for a dependable structural engineer team in Pittsburgh, give them a call!

For more information about Pittsburgh Design & Engineering Services, please visit: PittDES.com or the companies LinkedIn | Facebook

 
 
 

724-949-0004

412-677-0933

Email us

P.O BOX 112634

Pittsburgh PA 15241

  • Facebook
  • LinkedIn
  • Pittsburgh Structural Engineer- Instagram page
  • TikTok
  • Pittsburgh Structural Engineer- YouTube Channel

© 2019-2025  Pittsburgh Design & Engineering Services LLC. All Rights Reserved

bottom of page